Looking for a solution?

Where there's a problem there's a solution

  • Problem Description: When trying to launch FLUENT 12.0 on an AIX system you receive the following error:
    Cortex/aix51_64/cortex.3.9.2 because of the following errors:
    rtld: 0712-001 Symbol _GetCatName__FiPCc was referenced
    from module cortex.3.9.2(), but a runtime definition
    of the symbol was not found.
    rtld: 0712-001 Symbol __ct__Q2_3std8_LocinfoFPCci was referenced
    from module cortex.3.9.2(), but a runtime definition
    of the symbol was not found.

  • Resolution: Check the Operating System and Compiler versions on this system.
    For ANSYS FLUENT12.0 the Operating System should at least be at the version 5300-07-01-0748 and C/C++ compiler (XLC) at version 9.0.0.7 .